Heckmann Building Products Inc.
1501 N. 31st Avenue - Melrose Park, IL 60160 USA
800-621-4140  Fax 708-865-2640

Download PDF Format

POS-I-TIEŽ SPECIFICATION

SECTION 04085

MASONRY ANCHORS AND ACCESSORIES

PART 1 GENERAL

1.1 SECTION INCLUDES

A. Masonry veneer anchors and ties.

1.2 RELATED SECTIONS

A. Section 04810 - Unit Masonry Assemblies.

1.3 REFERENCES

*****************************************************************
NOTE: Delete references from the list below that are not actually required by the text of the edited section.
*****************************************************************

A.     ASCE/ACI 530.1 – Specifications for Masonry Structures; 1995.

B. ASTM A 153/A 153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware; 1998.

C. ASTM A 580/A 580M - Standard Specification for Stainless Steel Wire; 1998.

1.4 SUBMITTALS

A. Submit under provisions of Section 01300.

B. Product Data: Manufacturer's data on each type of product furnished.

PART 2 PRODUCTS

2.1 MANUFACTURER

A. Acceptable Manufacturer:
Heckmann Building Products Inc.,
1501 N. 31st Avenue
Melrose Park, IL 60160.
Tel: (708) 865-2403 Fax: 708-865-2640

Email: Heckmann@worldnet.att.net.
Website: www.heckmannbuildingprods.com.

*****************************************************************
NOTE: Delete paragraph below; coordinate with Division 1 requirements.
*****************************************************************

B. Requests for substitutions will be considered in accordance with provisions of Section 01600.

C. Substitutions: Not permitted.

2.2 APPLICATIONS

A. Provide anchoring systems that comply with ACI 530.1/ASCE 6/TMS 602.

B. Masonry Anchors

*****************************************************************
Note: ** Delete all of the following types that are not required.
*****************************************************************

1. Anchors to Concrete: No. 75: Heckmann "Pos-I-TieŽ" TapconŽ Screw.

2. Anchors to Masonry Backup: No. 75: Heckmann "Pos-I-TieŽ" TapconŽ Screw.

3. Anchors to Metal Stud Backup: No. 75: Heckmann "Pos-I-TieŽ" Self-Drilling Screw.

4. Anchors to Structural Steel: No. 75: Heckmann "Pos-I-TieŽ" Dril-ItŽ Screw.

5. Anchors to Wood Stud Backup: No. 75: Heckmann "Pos-I-TieŽ" TapconŽ Screw.

C. Masonry Ties

1.Masonry Veneer Ties: Provide minimum 2 inches (50 mm) embedment in mortar.

A. Wire 3/16 inch (4.75 mm) diameter x [Length]

*****************************************************************
Note: ** Delete all of the following types that are not required.
*****************************************************************

    1. No. 75 Pos-I-TieŽ Triangle Wire Tie
    2. No. 75 Pos-I-TieŽ Single Wire Tie

Other Applications: Where details or installation conditions require, provide ties fabricated of shape and size to suit conditions and provide adequate anchorage.

2. Masonry Veneer Seismic Ties: Continuous wire in mortar joint, anchored to Pos-I-TieŽ Triangle Tie with welded No. 370 Seismic clip.

*****************************************************************
Note: Select one of the following 3 combinations of materials: for wire ties.
*****************************************************************

A. Material for Ties in Exterior Walls: Stainless steel.

B. Material for Ties in Exterior Walls: Hot-dip galvanized.
C. Material for Ties Exposed to Air in Exterior Walls: Hot-dip galvanized.

D. Material for Ties Completely Embedded in Mortar Joints: Mill galvanized.

2.3 MATERIALS

1. Barrel Materials

Heckmann "No. 75 Pos-I-TieŽ": One-Piece Screw consisting of a 92% Zamac 2 Zinc barrel, washer, flanged head and eye to receive Pos-I-TieŽ wire tie; designed to seat barrel directly on structural portion of backup, with flanged head covering fastener hole.

1. Provide barrel shaft length [5/8 inch] [1 inch] [1-1/2 inch] [2 inch] [2-1/2 inch] [3 inch] and screws to suit substrate.

2. Wire Tie Materials

A. Stainless Steel: Type 304.

1. Wire: 3/16 inch (4.76 mm) diameter ASTM A 580/A 580M.

B. Hot-Dip Galvanized Steel: Hot-dip galvanized after fabrication in accordance with ASTM A 153/A 153M, Class B-2.

1. Wire: 3/16 inch (4.76 mm) diameter.

C. Mill Galvanized Steel:

1. Wire: ASTM A 641, regular coating; 3/16 inch (4.76 mm) diameter.

PART 3 EXECUTION

3.1 INSTALLATION

A. Pos-I-TieŽ Screws

    1. Self-Drilling Screw: Use a standard drill with a variable clutch adjustment and a Pos-I-TieŽ Chuck Adapter. Place the barrel end of the screw in the chuck adapter, drill through the gypsum board and into the metal stud.
    2. TapconŽ Screw: Use a standard hammer drill and a Pos-I-TieŽ Sleeve Tool with a Pos-I-Tie Chuck Adapter on the end. Set Drill to Hammer, slide off the chuck adapter sleeve and drill a 2" deep hole into the backup with a 3/16" (4.76 mm) masonry drillbit. Replace the sleeve/chuck adapter, switch the hammer mode off, and place the barrel end of the screw in the chuck adapter. Drill the screw into the hole.
    3. Dril-ItŽ Screw: Use a standard drill with a variable clutch adjustment and a Pos-I-TieŽ Chuck Adapter. Place the barrel end of the screw in the chuck adapter, and drill the screw into the structural member. (Some structural steel may require pre-drilling a pilot hole)
  1. Pos-I-TieŽ Wires
    1. Configure ties to prevent flow of water to anchor and to transfer lateral loads without excess mechanical play or deformation.

END OF SECTION

Heckmann Homepage

Š Copyright 1999 Heckmann Building Products Inc.