Heckmann Building Products Inc.
1501 N. 31st Avenue - Melrose Park, IL 60160 USA
800-621-4140  Fax 708-865-2640

Download PDF Format

Flashing Specifications

SECTION 04085

MASONRY ANCHORS AND ACCESSORIES

PART 1 GENERAL

1.1 SECTION INCLUDES

********************************************
NOTE: Delete items below not required for project.
*********************************************

A. Masonry veneer anchors and ties.

B. Stone veneer anchors and ties.

C. Masonry accessories.

1.2 RELATED SECTIONS

A. Section 04810 - Unit Masonry Assemblies.

B. Section 04851 - Cut Stone Veneer.

C. Section 04852 - Stone Masonry Veneer.

1.3 REFERENCES

*********************************************
NOTE: Delete references from the list below that are not actually required by the text of the edited section.
**********************************************

A. ASCE/ACI 530.1 – Specifications for Masonry Structures; 1995.

B. ASTM A 153/A 153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware; 1998.

C. ASTM A 167 - Standard Specification for Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip; 1996.

D. ASTM A 240/A 240M - Standard Specification for Heat-Resisting Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels; 1998b.

E. ASTM A 276 - Standard Specification for Stainless Steel Bars and Shapes; 1998b.

F. ASTM A 479/A 479M - Standard Specification for Stainless and Heat-Resisting Steel Bars and Shapes for Use in Boilers and Other Pressure Vessels; 1997a.

G. ASTM A 580/A 580M - Standard Specification for Stainless Steel Wire; 1998.

H. ASTM A 653/A 653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process; 1998.

I. ASTM B 633 – Standard Specification for Electrodeposited Coatings of Zinc on Iron and Steel; (Reapproved 1994).

1.4 SUBMITTALS

A. Submit under provisions of Section 01300.

B. Product Data: Manufacturer's data on each type of product furnished.

PART 2 PRODUCTS

2.1 MANUFACTURERS

A. Acceptable Manufacturer:
Heckmann Building Products Inc.,
1501 N. 31st Avenue
Melrose Park, IL 60160.
Tel: (708) 865-2403 Fax: 708-865-2640

Email: info@heckmannanchors.com.
Website:
www.heckmannanchors.com.

*********************************************
NOTE: Delete paragraph below; coordinate with Division 1 requirements.
**********************************************

B. Requests for substitutions will be considered in accordance with provisions of Section 01600.

C. Substitutions: Not permitted.

2.2 APPLICATIONS

A. Provide anchoring systems that comply with ACI 530.1/ASCE 6/TMS 602.

2.3 MATERIALS

A. Stainless Steel: Type 304.

1. Sheet Metal: ASTM A 167 or ASTM A 240/A 240M.

B. Mill Galvanized Steel:

1. Sheet Metal: ASTM A 653/A 653M, G60 coating.

2. Wire: ASTM A 641, regular coating; minimum 3/16 inch (4.76 mm) diameter.

C. Copper: ASTM B 370 Soft Temper; 16 oz and 20 oz.

D: Steel Sheet Metal Flashings:

1005 L-FLASHING
[Leg dimension] x [Leg dimension] x [length]

1008 L-FLASHING WITH DRIP
[Leg dimension] x [Leg dimension] x [drip dimension] x [length]

1009 U-FLASHING
[Leg dimension] x [Leg dimension] x [Leg dimension] x [length]

1010 Z-FLASHING WITH DRIP
[Leg dimension] x [Leg dimension] x [Leg dimension] x [drip dimension] x [length]

1011 ACUTE BEND FLASHING
[Leg dimension] x [Leg dimension] x [length]

1012 OBTUSE FLASHING
[Leg dimension] x [Leg dimension] x [length]

1017 HOOK-ON FLASHING W/DRIP
[Hook Dimension] x [Leg dimension] x [Leg dimension] x [drip dimension] x [length]

1020 HOOK-ON Z-FLASHING W/DRIP
[Hook Dimension] x [Leg dimension] x [Leg dimension] x [Leg dimension] x [drip dimension] x [length]

1022 Z-FLASHING W/DRIP
[Leg dimension] x [Leg dimension] x [Leg dimension] x [drip dimension] x [length]

1024 HOOK-ON Z-FLASHING W/DRIP
[Hook Dimension] x [Leg dimension] x [Leg dimension] x [Leg dimension] x [drip dimension] x [length]

1052 ANGLED FLASHING
[Leg dimension] x [Leg dimension] x [drip dimension] x [length]

1053 CRIMPED U-FLASHING
[Hook Dimension] x [Leg dimension] x [Leg dimension] x [Leg dimension] x [length]

1054 L-FLASHING W/DRIP
[Leg dimension] x [Leg dimension] x [drip dimension] x [length]

1055 SPECIAL FLASHING
[Leg dimension] x [Leg dimension] x [Leg dimension] x [Leg dimension] x [drip dimension] x [length]

1056 SPECIAL FLASHING
[Leg dimension] x [Leg dimension] x [Leg dimension] x [length]

Termination Bar

T-BAR
1/8 inch (3.175 mm) thick x 1-1/4 inch (32 mm) wide x [length] with [diameter] holes [length] on center.

PART 3 EXECUTION

3.1 INSTALLATION

A. Install as specified in applicable masonry section(s) and in accordance with manufacturer's instructions.

END OF SECTION

 

Home     Products    Specifications    Submittals     CAD Details     Test Data     PDF Files
Catalog # Index  
   M.S.D.S.     Credit App.     Links     Trades Shows     Contact     History

 

© Copyright 1999 Heckmann Building Products Inc.