HECKMANN BUILDING PRODUCTS INC.
1501 N. 31st Avenue
Melrose Park, IL 60160-2911
800-621-4140 and 708-865-2403
FAX: 708-865-2640
SUBMITTAL SHEET: N0. 367 CORE/CAVITY VENTTM WEEP SYSTEM
The Core/Cavity VentTM Weep System creates many openings at the lowest point of the core and cavity of the wall, continuously along the wall. See No. 365 Trash Mortar Diverter and No. 366 Cavity Vent Weep System for similar conditions.
|
![]() |
Installation:
Clean the installation surface.
Position the Core/Cavity VentTM on flashings and
waterstops with material centered on the block wall. Allow intermittent edges to extend
into the wall cavity and to the exterior as illustrated.
Apply bed joint of mortar.
Install masonry units on the bed of mortar, following normal installation procedures.
Tool and finish mortar joints.
Use a common utility knife to score Core/Cavity VentTM at
the wall line.
Break off excess Core/Cavity VentTM on the scored line.
The Core/Cavity Vent comes in 12" x 25 ft rolls ( 30.48 cm x 7.62 m) - 8 rolls (200 lin ft) per box.